    Quality difference in between Therapeutic Ultrasound Device

    Classification of tools

    Low cost tool

    High quality tool
    TendonCARE-Bio838
    (For musculoskeletal solution)

    Frequency

    Variance due to poor electrical control
    and simple electronic tracing range
    of resonance

    Expensive component of pulse
    generator in driving board and
    complex electronic control.
    Manual fine turning for very
    critical point of resonance

    Ultrasound propagation

    Superficial

    Deep up to 5cm or above

    Intensity

    May out of therapeutic range and attenuation

    Limited within therapeutic range

    Heat generation of horn

    Horn self-heating due to over drive of
    crystal in control, thermal effect
    caused more serious inflammation

    Apply pulsed shockwave technology,
    non-thermal effect for
    best biological effects

    Intensity (SATA)
    Averaged intensity over ultrasound
    field during pulsed repetition period

    Provides only electrical output power

    Apply effective ultrasound power
    Average output of pause and working

    Intensity adjustment

    Constant power programed with time pause
    by mean of average of duty cycle

    Programed variance of power
    intensity with output consistency

    Pulse rate
    (Affected time for gas bubble grow)

    Low
    unstable cavitation
    time long for large bubble size grow
    up caused cell damage

    High
    stable cavitation
    suppressed with very short cycle duration
    that limited bubble size in micro

    Acoustic cavitation
    (The formation of tiny gas bubbles)

    Produces toxic free radicals in the
    tissue due to shock wave with high
    local temperature

    Improves blood flow of capillary;
    Beneficial to soft tissue healing
    and helps protein production

    Acoustic steaming
    (localized liquid flow around
    the vibrating bubbles)

    Bulk steaming
    (far less mechanically powerful)
    (A movement of fluid)
    Distortion of cell membrane and influencing
    ion fluxes and intracellular activity

    Micro streaming
    (Form eddies of flow)
    Can only alter cell membrane permeability
    and stimulate the cell activity

    LIPUS therapeutic effects

    No or out of biological effects

    Yes, under specification of
    medical research

    Result of application

    Caused cell membrane damage due
    to unstable cavitation
    (without felt pain during treatment)
    or prolonged healing period

     

    Speedup healing time
    Speedup protein synthesis

     

         
         

    Medical Research from LIPUS application

     

     

    Confocal laser scanning
    microscope images (I)

    Green (living cells)
    Red (dead cells)

    After 14 days of LIPUS stimulation,
    B) abundant elongated chondrocytes
    around injured sites were observed
    whereas the control group
    A) showed few chondrocytes migration

    Confocal laser scanning
    microscope images (II)

    Green (living cells)
    Red (dead cells)

     

    Images of area covered by chondrocyte migration in a monolayer culture
    plate.

    With 2 mm cell scrapper, the scratched area was almost fully covered by chondrocyte migration for 2 days

     

    Bone fracture healing with LIPUS application

    Histological findings at 3 days after surgery with bone allograft (proliferating
    cell nuclear antigen (PCNA) immunohistochemical staining) and at 5 days after surgery
    with bone allograft (Hematoxylin & Eosin [H&E] staining)

     

     

     

     
    在這裡插入商標

    • Home Page
    • TendonCARE
      Bio-838
    • TendonCARE
      Bio-838
    • TendonCARE
      Bio-838
    • TendonCARE
      Bio-838
    • TendonCARE
      Bio-838
    • Ultrasound Therapy
    • Quality in between Ultrasound Devices

    • Q&A Terms

    • Download

    • Specification

    • Contact us

    • Order fm Ebay: Tendoncare

     






























    Designed for Internet Explorer 6